Can you spot the problem#10

Initial Structural design
Arch design

Did you find anything missing from the above Design?

The Roof has slopes. But there is no consideration for gutter provision and its support.

We figure out this issue and raise RFI against this issue.

RFI regarding the missing consideration of Gutter and its fixing

Client approves to make changes in the design and send us back. See below revised design